General usage steps of water-cooled resistors
2. Installation orientation. The installation direction of most water-cooled resistors is specified. Incorrect installation can lead to reduced resistor performance, inability to function properly, or even damage to the equipment. For the SL type high-frequency high-power water-cooled resistor, it should be installed vertically on the installation plane. The cooling water should enter from the lower port and exit from the upper port.
2. Cooling water. The SL type high-frequency high-power oxide film water-cooled resistor has inlet and outlet water connections. When installing, please follow the markings to ensure correct connection and avoid errors.
3. Electrode device. The SL type high-frequency high-power oxide film water-cooled resistor has a large power and current. During connection, the cable and the outgoing terminal must ensure a reliable electrical connection to prevent excessive contact resistance. During operation, the electrodes heat up, causing the shell to deform due to heat and leading to the failure of the product.
4. Usage process. When using, it is necessary to first release the air. That is, start by circulating the cooling water, and wait until the circulating water fills the interior of the resistor before powering it on. Avoid damaging the resistor due to dry burning.
5. Cooling water flow rate. Most of the heat generated during the operation of the SL type high-frequency high-power oxide film water-cooled resistor is dissipated by the cooling water. Its power consumption is relatively less affected by the environment within the operating temperature range, and it is related to the inlet water temperature, water flow rate and flow volume. Calculation should be conducted before use. Ensure that the outlet water temperature is below 70 degrees during normal operation.
6. First, cut off the power supply and then stop the cooling water supply. This is to prevent the resistor from burning out.
7. Reduce power. When the water temperature is high, the water flow is too low, or the environment and temperature exceed the specified operating temperature, the power should be reduced for operation.
Related Posts